Fuji frenic inverter manual. Fuji Electric FRENIC 2019-02-02

Fuji frenic inverter manual Rating: 9,2/10 622 reviews

FRENIC

fuji frenic inverter manual

For other inverter types, perform wiring in accordance with their individual terminal arrangement. These values are determined by inverter model and specifications built-in or external type of braking resistors. When the total time is time 10000 hours or more display: 10. Torque Boost In Auto-Tuning : This function automatically optimizes the output voltage to fit the motor with its load. Enable the retry function H04. This feature has a wide range of applications; including conveyors and high-inertia loads that demand high starting torque.

Next

Frenic 5000G11 Series by Fuji Electric. In stock. Optimal toque

fuji frenic inverter manual

Fuji motors motor do not require the use of output circuit filters because of their good insulation. Slip Compensation Shortens Setting Time The slip compensation controller works with voltage tuning for even more accurate speed control at low velocity. Depending on Quick response the inertia of the moving loads or the coupling state, the revolution may be unstable. Take care of the following items during work. Otherwise, a fire or an accident might result. Possible Causes What to Check and Suggested Measures 1 An alarm function of the Inspect external equipment operation. The menu for function selection will be dis- played.

Next

Fuji Electric FRENIC

fuji frenic inverter manual

Therefore, if a control signal cable or wire comes into direct contact with a live conductor of the main circuit, the insulation of the sheath or the cover might break down, which would expose the signal wire to a high voltage of the main circuit. Grounding terminal G Be sure to ground either of the two grounding terminals for safety and noise reduction. Consider the use of a braking resistor. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. Contact your Fuji Electric representative for de- tors special tails. Further, it is also possible to display alarm information that indicates the status of the inverter when the alarm condition occurred. In Running mode, press the key to enter Programming mode.

Next

FRENIC

fuji frenic inverter manual

This icon indicates information which, if not heeded, can result in the inverter not operating to full efficiency, as well as information concerning incorrect operations and settings which can result in accidents. Icons The following icons are used throughout this manual. The auto energy saving operation is designed for use with the frequency lower than the base frequency. Reconsider the choice of the braking resistor in order to improve braking ability. To maintain stable and reliable operation and avoid unexpected failures, daily and periodic maintenance must be performed. Thanks forwardly, Bobansent 2 manuals; been too long ago, not sure if these are right ones for you. This icon indicates a reference to more detailed information.

Next

Fuji Frenic manual?

fuji frenic inverter manual

The Dynamic torque-vector control promises optimum motor control under any operating conditions, with reduced motor speed. I think the problem is an adjustment rather than a fault. Correct any incorrect function code data settings e. All products and company names mentioned in this manual are trademarks or registered trademarks of their respective holders. Enable the retry function H04.

Next

FUJI ELECTRIC FRENIC

fuji frenic inverter manual

Motor Parameters Slip compensation gain Sets the gain to compensate for the motor slip frequency. The lowest digit will blink. The 500G11 is equipped with many features including. If the base frequency is higher than 60 Hz, then you may get little or no energy saving effect. Initialize all function code data to the factory defaults. When using an external braking resistor, arrange the inverter and braking resistor to keep the wiring length to 5 m or less and twist the two wires or route them together in parallel. In Running mode, press the key to enter Programming mode.

Next

Fuji Electric Inverters / VFD

fuji frenic inverter manual

If H03 is set to: Function Disable initialization Settings made by the user manually will be retained. Under light load, auto torque boost decreases the output voltage to prevent the motor from over-excitation. For the braking resistor built-in type, refer to the next page. The functions can be easily selected with the menu-driven system. Correct any incorrect function code data settings e. It is necessary to take special measures suitable for this Synchronous mo- In running motor type.

Next

FujiFilm FRENIC

fuji frenic inverter manual

The inverter automatically exits from Alarm mode and restarts without issuing a block alarm even if it has entered the forced Alarm mode. If it is enabled, entering a run command will run the inverter to drive the motor for the period preset to the timer. Set the starting frequency to a level that will enable the motor to generate enough torque for startup. In Running mode, you can: 1 Monitor the running status e. Possible Causes What to Check and Suggested Measures 1 Braking load was too Recalculate the relation between the braking load and braking capacity. Hello guys Sorry for revival old thread, but on the net there is no much document for Frenic5000M2 drive.

Next