Leica asp300 service manual. Leica ASP300 S 2019-02-09

Leica asp300 service manual Rating: 4,9/10 1587 reviews

LEICA ASP300 S OPERATING MANUAL Pdf Download.

leica asp300 service manual

Setting up the instrument 4. Operation Allocation of reagents to the correct reagent group is the basis for compatibility monitoring. During a smart clean, a series of air cleaning steps will be applied which will remove any excess liquid condensate from all internal tubing. Also, rebuild the rotary gear with a new selector and port selector. Make sure to read these instructions, even if you are already familiar with the operation and use of other Leica products. First thing to do is just rebuild all the air valves. And owners of Leica X-Cameras can make use of various redesign options for their camera with Leica X à la carte.

Next

Leica ASP300 S

leica asp300 service manual

I guess at some point Leica has upgraded the units to different valves. MedWrench is available to help people with specific questions and troubleshooting problems. In the entry window, set a new finish time. Occassionally, even Leica products need someone to tend to them. The pro- gram itself is not deleted.

Next

General Services // Services // Service & Support

leica asp300 service manual

Improve specimen quality and laboratory economy with the Reagent Management System and quick start for commonly used programs. That is why Leica maintains a worldwide service network of factory-trained experts. I have pictures of the valves I can run the rapid wash and the unit will run without fault but as the customer runs a cycle the above fault appears. These settings must be modified by experienced operators only. The individual options are described in chapter 5.

Next

Leica Biosystems Tissue Processor ASP300 S

leica asp300 service manual

This will also help other community members who face similar challenges. Make sure the mating surface of the rotary selector disk and the metal are clean and smooth. Clean programs cannot be copied or deleted. How to order The new outfit for your Leica is only a click away. For more information please contact your Leica Dealer or Customer Care.

Next

Leica ASP 300 support documentation

leica asp300 service manual

Allocation to the wrong reagent group can lead to reagent cross contamination. Checking the drip tray Regularly check the drip tray 16 for spilled reagents. Remember that it is not possible to delete a step from a program containing only one single step. The control software contains an on-line help feature where detailed information on the operation of each screen, on error messages and on the software functions can be found. I have checked the rotary vlave no leaks the bottles all seat correctly, lids are all tight. Minimal reagent carryover — achieved by the software-controlled 3-step draining process of the retort and by the retort design itself — also helps achieve superior specimen quality every time.

Next

Leica tissue processor ASP300s

leica asp300 service manual

Do you know if it is possible to upgrade the unit to the new valves? Use the in- cluded funnel for clean filling. A printer option will be dis- played only, if a printer has been configured for the in- strument. Simply access and order your own printed brochure today. I could obviously order them at very expensive cost but i would like to know if they will fit and if it will cure my problems. The quickest way to get informed is to take a look at the.

Next

Leica ASP300 S

leica asp300 service manual

The serial number of the instrument and the cur- rent software version are entered at the factory and cannot be edited. They can provide information on availability and delivery times for the products you require. Do not use acetone, benzene or trichlorethane in the instrument! Always wear rubber gloves and safety goggles when handling the chemicals used in this instrument. It is a strange thing. Programs must consist of at least one step.

Next

Leica

leica asp300 service manual

For detailed instructions on each individual parameter, refer to the On-line help feature. Designed for routine and research histopathology of up to 300 cassettes Proven technology combined with top quality components. A message will be displayed indicating that the changes will only affect the currently running program. The printer option will be displayed only, if a printer has been configured for the instrument. Dispose of waste solvents with care according to local regulations and the waste management policy of the company or institution. Add or alter engravings such as signatures or names.

Next

Leica ASP300 S

leica asp300 service manual

Could you please be more specific with the issue that you are having with your instrument , and the MedWrench team will do their best to assist you in solving the issue. Request quote If you would like a sales quotation or have questions about our lab equipment, please fill out the form below and one of our lab equipment professionals will contact you within 24 hours. Carmelo, I have seen this before. Engraving One personalisation option is a custom engraving on the flash cover or the top cover of the camera. Finally they went to Burkert valves these are maint free.

Next